| Test Range | 2.5 mm to 5 meter (in steel). In Hot Key mode it has 13 preset values. Fine mode adjustable in step of 1mm. |
| Velocity | 1000 m/s to 9999 m/s. In Hot Key mode it has 7 preset values. Fine mode adjustable in step of 1 m/s. |
| Delay | Up to 3 meter adjustable in 0.5mm or 5mm step. |
| Gain | 100 dB calibrated gain adjustable in 0.1, 0.5, 1, 2, 6 or 14 dB step. |
| Rejection | 0 to 100% FSH with LED indicator. |
| Rectification | Fullwave rectified with filtering. |
| Frequency | 0.5 MHz to 15 MHz (Wideband). |
| Linearity deviation | Vertical: 3%,Horizontal: 0.5%. |
| Test Modes | Pulse echo and transmit/receive. |
| Connectors | LEMO Size 00 (2 nos). |
| Monitor | Dual gate adjustable in 1% of Screen width with Positive/Negative logic, Gate Expand modes. |
| Gate Expand | Expands Range to width of the gate. |
| A-Scan memory | 500 Trace Patterns can be stored, recalled or transferred to PC via USB port. A-Scan trace pattern can be directly stored on SD card or on External USB disk. |
| Calibration Set-up | 50 different calibration set-ups can be Stored and Recalled. |
| Software | ArjnSoft Interface software for transferring A-Scan from Arjun10 to PC is supplied. |
| USB and SD card | External USB disk and Micro SD card (upto 8GB) ports provided for data storage. |
| Display | 5 inch Colour Wide VGA LCD/TFT display (800×480 pixel, size 108×64 mm) with higher resolution LCD for better signal representation and better visibility with different colour sets. |
| Reference A-Scan | Reference A-Scan pattern of standard test object can saved and recalled in the background for easy comparisons during testing. |
| Echo Dynamic | Echo Dynamic pattern display. |
| DAC | Dynamic DAC curve can be Digitally plotted(Smooth parabolic curve) on screen with selectable additional offset curves from 0 to 14 dB in 0.5 dB selectable steps. DAC curve can be set as flaw monitor gate. DAC curve can be plotted using minimum 2 to maximum 10 points. |
| Digital Readout And Trig. Function | Thickness/Depth can be displayed in digital readout when using a normal probe and Beam path, Surface Distance and Depth are directly displayed when angle probe is in use. |
| Update Rate | 50Hz. |
| Power | Lithium-Ion Battery pack 7.4VDC,5AH, gives 10 hours continuous operation from fully charged battery and External charger is provided to charge the battery with out engaging the main unit. |
| Charger | Input Voltage 100 to 240 VAC. Charge status indicator is provided. |
| Temperature | 0 to 55°C. |
| Size | 117 x 176 x 56 mm (HxWxD). |
| Weight | 800 gms with Battery. |